General information |
Product type designation | CPU 1517H-3 PN |
HW functional status | FS06 |
Firmware version | V3.1 |
● FW update possible | Yes |
Product function |
● I&M data | Yes; I&M0 to I&M3 |
● Isochronous mode | No |
● SysLog | Yes |
Engineering with |
● STEP 7 TIA Portal configurable/integrated from version | V19 (FW V3.1) / V15.1 (FW V2.6) or higher |
Display |
Screen diagonal [cm] | 6.1 cm |
Control elements |
Number of keys | 6 |
Mode selector switch | 1 |
Supply voltage |
Rated value (DC) | 24 V |
permissible range, lower limit (DC) | 19.2 V |
permissible range, upper limit (DC) | 28.8 V |
Reverse polarity protection | Yes |
Mains buffering |
● Mains/voltage failure stored energy time | 5 ms |
● Repeat rate, min. | 1/s |
Input current |
Current consumption (rated value) | 1.5 A |
Current consumption, max. | 1.9 A |
Inrush current, max. | 1.9 A; Rated value |
I²t | 0.4 A²·s |
Power |
Infeed power to the backplane bus | 12 W |
Power consumption from the backplane bus (balanced) | 30 W |
Power loss |
Power loss, typ. | 24 W |
Memory |
Number of slots for SIMATIC memory card | 1 |
SIMATIC memory card required | Yes |
Work memory |
● integrated (for program) | 2 Mbyte |
● integrated (for data) | 8 Mbyte |
Load memory |
● Plug-in (SIMATIC Memory Card), max. | 32 Gbyte |
Backup |
● maintenance-free | Yes |
CPU processing times |
for bit operations, typ. | 4 ns |
for word operations, typ. | 6 ns |
for fixed point arithmetic, typ. | 6 ns |
for floating point arithmetic, typ. | 24 ns |
CPU-blocks |
Number of elements (total) | 12 000; Blocks (OB, FB, FC, DB) and UDTs |
DB |
● Number range | Number range: 1 to 59 999 |
● Size, max. | 8 Mbyte; For non-optimized block accesses, the max. size of the DB is 64 KB |
FB |
● Number range | 0 ... 65 535 |
● Size, max. | 1 Mbyte |
FC |
● Number range | 0 ... 65 535 |
● Size, max. | 1 Mbyte |
OB |
● Size, max. | 1 Mbyte |
● Number of free cycle OBs | 100 |
● Number of time alarm OBs | 20 |
● Number of delay alarm OBs | 20 |
● Number of cyclic interrupt OBs | 20; with minimum OB 3x cycle of 1 ms |
● Number of process alarm OBs | 50 |
● Number of DPV1 alarm OBs | 3 |
● Number of startup OBs | 100 |
● Number of asynchronous error OBs | 4 |
● Number of synchronous error OBs | 2 |
● Number of diagnostic alarm OBs | 1 |
Nesting depth |
● per priority class | 24 |
Counters, timers and their retentivity |
S7 counter |
● Number | 2 048 |
Retentivity |
— adjustable | Yes |
IEC counter |
● Number | Any (only limited by the main memory) |
Retentivity |
— adjustable | Yes |
S7 times |
● Number | 2 048 |
Retentivity |
— adjustable | Yes |
IEC timer |
● Number | Any (only limited by the main memory) |
Retentivity |
— adjustable | Yes |
Data areas and their retentivity |
Retentive data area (incl. timers, counters, flags), max. | 768 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 700 KB |
Flag |
● Size, max. | 16 kbyte |
● Number of clock memories | 8; 8 clock memory bit, grouped into one clock memory byte |
Data blocks |
● Retentivity adjustable | Yes |
● Retentivity preset | No |
Local data |
● per priority class, max. | 64 kbyte; max. 16 KB per block |
Address area |
Number of IO modules | 8 192; max. number of modules / submodules |
I/O address area |
● Inputs | 32 kbyte; All inputs are in the process image |
● Outputs | 32 kbyte; All outputs are in the process image |
per integrated IO subsystem |
— Inputs (volume) | 16 kbyte |
— Outputs (volume) | 16 kbyte |
Subprocess images |
● Number of subprocess images, max. | 31 |
Hardware configuration |
Number of distributed IO systems | 64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET, but also by the connection of I/O via IE/PB-Links. |
Number of IO Controllers |
● integrated | 1 |
Rack |
● Modules per rack, max. | 9; CPU + 2 PS + 6 CP |
Time of day |
Clock |
● Type | Hardware clock |
● Backup time | 6 wk; At 40 °C ambient temperature, typically |
● Deviation per day, max. | 10 s; Typ.: 2 s |
Operating hours counter |
● Number | 16 |
Clock synchronization |
● supported | Yes |
● on Ethernet via NTP | Yes |
Interfaces |
Number of PROFINET interfaces | 2 |
1. Interface |
Interface types |
● RJ 45 (Ethernet) | Yes; X1 |
● Number of ports | 2 |
● integrated switch | Yes |
Protocols |
● IP protocol | Yes; IPv4 |
● PROFINET IO Controller | Yes |
● PROFINET IO Device | No |
● SIMATIC communication | Yes; Only Server |
● Open IE communication | Yes; Optionally also encrypted |
● Web server | Yes |
● Media redundancy | Yes |
PROFINET IO Controller |
Services |
— Isochronous mode | No |
— IRT | No |
— PROFIenergy | Yes; per user program |
— Number of connectable IO Devices, max. | 256 |
— Updating times | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data |
— PROFINET Security Class | 1 |
Update time for RT |
— for send cycle of 1 ms | 1 ms to 512 ms |
2. Interface |
Interface types |
● RJ 45 (Ethernet) | Yes; X2 |
● Number of ports | 1 |
● integrated switch | No |
Protocols |
● IP protocol | Yes; IPv4 |
● PROFINET IO Controller | No |
● PROFINET IO Device | No |
● SIMATIC communication | Yes; Only Server |
● Open IE communication | Yes; Optionally also encrypted |
● Web server | Yes |
● Media redundancy | No |
3. Interface |
Interface type | Pluggable synchronization submodule (FO) |
Plug-in interface modules | Synchronization module 6ES7960-1CB00-0AA5, 6ES7960-1FB00-0AA5 or 6ES7 960-1FE00-0AA5 |
4. Interface |
Interface type | Pluggable synchronization submodule (FO) |
Plug-in interface modules | Synchronization module 6ES7960-1CB00-0AA5, 6ES7960-1FB00-0AA5 or 6ES7960-1FE00-0AA5 |
Interface types |
RJ 45 (Ethernet) |
● 100 Mbps | Yes |
● Autonegotiation | Yes |
● Autocrossing | Yes |
● Industrial Ethernet status LED | Yes |
Protocols |
PROFIsafe | No |
Number of connections |
● Number of connections, max. | 320; via integrated interfaces of the CPU and connected CPs |
● Number of connections reserved for ES/HMI/web | 10 |
● Number of connections via integrated interfaces | 288 |
● Number of S7 routing paths | 64 |
Redundancy mode |
● PROFINET system redundancy (S2) | Yes |
● PROFINET system redundancy (R1) | Yes |
Media redundancy |
— MRP | Yes; MRP Automanager according to IEC 62439-2 Edition 2.0 |
— MRP interconnection, supported | Yes; as MRP ring node according to IEC 62439-2 Edition 3.0 |
— MRPD | No |
— Switchover time on line break, typ. | 200 ms; PROFINET MRP |
— Number of stations in the ring, max. | 50 |
SIMATIC communication |
● PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
● S7 routing | Yes |
● S7 communication, as server | Yes |
● S7 communication, as client | No |
Open IE communication |
● TCP/IP | Yes |
— Data length, max. | 64 kbyte |
— several passive connections per port, supported | Yes |
● ISO-on-TCP (RFC1006) | Yes |
— Data length, max. | 64 kbyte |
● UDP | Yes |
— Data length, max. | 2 kbyte; 1 472 bytes for UDP broadcast |
— UDP multicast | Yes; 128 multicast circuits (of which max. 5 via X1) |
● DHCP | No |
● DNS | Yes |
● SNMP | Yes |
● DCP | Yes |
● LLDP | Yes |
● Encryption | Yes; Optional |
Web server |
● HTTP | No |
● HTTPS | Yes; only via Web API |
● web API | Yes |
— Number of sessions, max. | 200 |
— number of simultaneous HTTP calls, max. | 4 |
— HTTP request body, max. | 131 072 byte |
OPC UA |
● Runtime license required | Yes; "Large" license required per CPU |
● OPC UA Client | No |
● OPC UA Server | Yes; Data access (read, write, subscribe), method call, custom address space |
— Application authentication | Yes |
— Security policies | available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256, Aes128Sha256RsaOaep, Aes256Sha256RsaPss |
— User authentication | "anonymous" or by user name & password |
— GDS support (certificate management) | No |
— Number of sessions, max. | 32 |
— Number of subscriptions per session, max. | 25 |
— Sampling interval, min. | 25 ms |
— Publishing interval, min. | 25 ms |
— Number of server methods, max. | 100 |
— Number of inputs/outputs per server method, max. | 20 |
— Number of monitored items, recommended max. | 5 000; for 1 s sampling interval and 1 s send interval |
— Number of server interfaces, max. | 10 of each "Server interfaces" / "Companion specification" type and 20 of the type "Reference namespace" |
— Number of nodes for user-defined server interfaces, max. | 30 000 |
● Alarms and Conditions | No |
Further protocols |
● MODBUS | Yes; MODBUS TCP |
S7 message functions |
Number of login stations for message functions, max. | 64 |
number of subscriptions, max. | 750 |
number of tags/attributes for subscriptions, max. | 20 000 |
Program alarms | Yes |
Number of configurable program messages, max. | 10 000; Program messages are generated by the "Program_Alarm" block, ProDiag or GRAPH |
Number of loadable program messages in RUN, max. | 10 000 |
Number of simultaneously active program alarms |
|
● Number of program alarms | 2 000 |
● Number of alarms for system diagnostics | 1 000 |
Test commissioning functions |
Joint commission (Team Engineering) | No |
Status block | Yes; Up to 16 simultaneously |
Single step | No |
Number of breakpoints | 20; Breakpoints are only supported in RUN-Solo status |
Status/control |
● Status/control variable | Yes |
● Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
● Number of variables, max. |
|
— of which status variables, max. | 200; per job |
— of which control variables, max. | 200; per job |
Forcing |
● Forcing | Yes |
● Forcing, variables | Peripheral inputs/outputs |
● Number of variables, max. | 200 |
Diagnostic buffer |
● present | Yes |
● Number of entries, max. | 3 200 |
— of which powerfail-proof | 1 000 |
Traces |
● Number of configurable Traces | 8 |
● Memory size per trace, max. | 512 kbyte |
Interrupts/diagnostics/status information |
Diagnostics indication LED |
● RUN/STOP LED | Yes |
● ERROR LED | Yes |
● MAINT LED | Yes |
● Connection display LINK TX/RX | Yes |
Supported technology objects |
Motion Control | No |
Controller |
|
● PID_Compact | Yes; Universal PID controller with integrated optimization |
● PID_3Step | Yes; PID controller with integrated optimization for valves |
● PID-Temp | Yes; PID controller with integrated optimization for temperature |
Counting and measuring | Yes |
Standards, approvals, certificates |
Ecological footprint |
● environmental product declaration | Yes |
Global warming potential |
— global warming potential, (total) [CO2 eq] | 570 kg |
— global warming potential, (during production) [CO2 eq] | 96.9 kg |
— global warming potential, (during operation) [CO2 eq] | 483 kg |
— global warming potential, (after end of life cycle) [CO2 eq] | -9.97 kg |
Ambient conditions |
Ambient temperature during operation |
● horizontal installation, min. | 0 °C |
● horizontal installation, max. | 60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off |
● vertical installation, min. | 0 °C |
● vertical installation, max. | 40 °C; Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off |
Ambient temperature during storage/transportation |
● min. | -40 °C |
● max. | 70 °C |
Altitude during operation relating to sea level |
● Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
configuration / header |
configuration / programming / header |
Programming language |
— LAD | Yes |
— FBD | Yes |
— STL | Yes |
— SCL | Yes |
— CFC | Yes |
— GRAPH | Yes |
Know-how protection |
● User program protection/password protection | Yes |
● Copy protection | No |
● Block protection | Yes |
Access protection |
● protection of confidential configuration data | Yes |
● Password for display | Yes |
● Protection level: Write protection | Yes |
● Protection level: Read/write protection | Yes |
● Protection level: Write protection for Failsafe | No |
● Protection level: Complete protection | Yes |
● User administration | Yes |
programming / cycle time monitoring / header |
● lower limit | adjustable minimum cycle time |
● upper limit | adjustable maximum cycle time |
Dimensions |
Width | 210 mm |
Height | 147 mm |
Depth | 129 mm |
Weights |
Weight, approx. | 2 094 g; Interface modules: 2x 18 g |