Your Shopping Cart (0) Items
Your Shopping Cart Is Empty.
Preferential_Pricing $0.00
Total $0.00

SIEMENS S7-1500RH Redundant system CPU Module 6ES7517-3HP00-0AB0

15 review

Product Code:

107388.71 0.00
SIMATIC S7-1500H, CPU 1517H-3 PN, central processing unit with 2 MB work memory for program and 8 MB for data, 1st interface: PROFINET RT with 2-port switch, 2nd interface: PROFINET, 3rd/4th interface: H-SYNC, SIMATIC Memory Card required
Quantity

Subtotal: $107388.71

Product details

General information
Product type designationCPU 1517H-3 PN
HW functional statusFS06
Firmware versionV3.1
● FW update possibleYes
Product function
● I&M dataYes; I&M0 to I&M3
● Isochronous modeNo
● SysLogYes
Engineering with
● STEP 7 TIA Portal configurable/integrated from versionV19 (FW V3.1) / V15.1 (FW V2.6) or higher
Display
Screen diagonal [cm]6.1 cm
Control elements
Number of keys6
Mode selector switch1
Supply voltage
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Mains buffering
● Mains/voltage failure stored energy time5 ms
● Repeat rate, min.1/s
Input current
Current consumption (rated value)1.5 A
Current consumption, max.1.9 A
Inrush current, max.1.9 A; Rated value
I²t0.4 A²·s
Power
Infeed power to the backplane bus12 W
Power consumption from the backplane bus (balanced)30 W
Power loss
Power loss, typ.24 W
Memory
Number of slots for SIMATIC memory card1
SIMATIC memory card requiredYes
Work memory
● integrated (for program)2 Mbyte
● integrated (for data)8 Mbyte
Load memory
● Plug-in (SIMATIC Memory Card), max.32 Gbyte
Backup
● maintenance-freeYes
CPU processing times
for bit operations, typ.4 ns
for word operations, typ.6 ns
for fixed point arithmetic, typ.6 ns
for floating point arithmetic, typ.24 ns
CPU-blocks
Number of elements (total)12 000; Blocks (OB, FB, FC, DB) and UDTs
DB
● Number rangeNumber range: 1 to 59 999
● Size, max.8 Mbyte; For non-optimized block accesses, the max. size of the DB is 64 KB
FB
● Number range0 ... 65 535
● Size, max.1 Mbyte
FC
● Number range0 ... 65 535
● Size, max.1 Mbyte
OB
● Size, max.1 Mbyte
● Number of free cycle OBs100
● Number of time alarm OBs20
● Number of delay alarm OBs20
● Number of cyclic interrupt OBs20; with minimum OB 3x cycle of 1 ms
● Number of process alarm OBs50
● Number of DPV1 alarm OBs3
● Number of startup OBs100
● Number of asynchronous error OBs4
● Number of synchronous error OBs2
● Number of diagnostic alarm OBs1
Nesting depth
● per priority class24
Counters, timers and their retentivity
S7 counter
● Number2 048
Retentivity
— adjustableYes
IEC counter
● NumberAny (only limited by the main memory)
Retentivity
— adjustableYes
S7 times
● Number2 048
Retentivity
— adjustableYes
IEC timer
● NumberAny (only limited by the main memory)
Retentivity
— adjustableYes
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.768 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 700 KB
Flag
● Size, max.16 kbyte
● Number of clock memories8; 8 clock memory bit, grouped into one clock memory byte
Data blocks
● Retentivity adjustableYes
● Retentivity presetNo
Local data
● per priority class, max.64 kbyte; max. 16 KB per block
Address area
Number of IO modules8 192; max. number of modules / submodules
I/O address area
● Inputs32 kbyte; All inputs are in the process image
● Outputs32 kbyte; All outputs are in the process image
per integrated IO subsystem
— Inputs (volume)16 kbyte
— Outputs (volume)16 kbyte
Subprocess images
● Number of subprocess images, max.31
Hardware configuration
Number of distributed IO systems64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET, but also by the connection of I/O via IE/PB-Links.
Number of IO Controllers
● integrated1
Rack
● Modules per rack, max.9; CPU + 2 PS + 6 CP
Time of day
Clock
● TypeHardware clock
● Backup time6 wk; At 40 °C ambient temperature, typically
● Deviation per day, max.10 s; Typ.: 2 s
Operating hours counter
● Number16
Clock synchronization
● supportedYes
● on Ethernet via NTPYes
Interfaces
Number of PROFINET interfaces2
1. Interface
Interface types
● RJ 45 (Ethernet)Yes; X1
● Number of ports2
● integrated switchYes
Protocols
● IP protocolYes; IPv4
● PROFINET IO ControllerYes
● PROFINET IO DeviceNo
● SIMATIC communicationYes; Only Server
● Open IE communicationYes; Optionally also encrypted
● Web serverYes
● Media redundancyYes
PROFINET IO Controller
Services
— Isochronous modeNo
— IRTNo
— PROFIenergyYes; per user program
— Number of connectable IO Devices, max.256
— Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
— PROFINET Security Class1
Update time for RT
— for send cycle of 1 ms1 ms to 512 ms
2. Interface
Interface types
● RJ 45 (Ethernet)Yes; X2
● Number of ports1
● integrated switchNo
Protocols
● IP protocolYes; IPv4
● PROFINET IO ControllerNo
● PROFINET IO DeviceNo
● SIMATIC communicationYes; Only Server
● Open IE communicationYes; Optionally also encrypted
● Web serverYes
● Media redundancyNo
3. Interface
Interface typePluggable synchronization submodule (FO)
Plug-in interface modulesSynchronization module 6ES7960-1CB00-0AA5, 6ES7960-1FB00-0AA5 or 6ES7 960-1FE00-0AA5
4. Interface
Interface typePluggable synchronization submodule (FO)
Plug-in interface modulesSynchronization module 6ES7960-1CB00-0AA5, 6ES7960-1FB00-0AA5 or 6ES7960-1FE00-0AA5
Interface types
RJ 45 (Ethernet)
● 100 MbpsYes
● AutonegotiationYes
● AutocrossingYes
● Industrial Ethernet status LEDYes
Protocols
PROFIsafeNo
Number of connections
● Number of connections, max.320; via integrated interfaces of the CPU and connected CPs
● Number of connections reserved for ES/HMI/web10
● Number of connections via integrated interfaces288
● Number of S7 routing paths64
Redundancy mode
● PROFINET system redundancy (S2)Yes
● PROFINET system redundancy (R1)Yes
Media redundancy
— MRPYes; MRP Automanager according to IEC 62439-2 Edition 2.0
— MRP interconnection, supportedYes; as MRP ring node according to IEC 62439-2 Edition 3.0
— MRPDNo
— Switchover time on line break, typ.200 ms; PROFINET MRP
— Number of stations in the ring, max.50
SIMATIC communication
● PG/OP communicationYes; encryption with TLS V1.3 pre-selected
● S7 routingYes
● S7 communication, as serverYes
● S7 communication, as clientNo
Open IE communication
● TCP/IPYes
— Data length, max.64 kbyte
— several passive connections per port, supportedYes
● ISO-on-TCP (RFC1006)Yes
— Data length, max.64 kbyte
● UDPYes
— Data length, max.2 kbyte; 1 472 bytes for UDP broadcast
— UDP multicastYes; 128 multicast circuits (of which max. 5 via X1)
● DHCPNo
● DNSYes
● SNMPYes
● DCPYes
● LLDPYes
● EncryptionYes; Optional
Web server
● HTTPNo
● HTTPSYes; only via Web API
● web APIYes
— Number of sessions, max.200
— number of simultaneous HTTP calls, max.4
— HTTP request body, max.131 072 byte
OPC UA
● Runtime license requiredYes; "Large" license required per CPU
● OPC UA ClientNo
● OPC UA ServerYes; Data access (read, write, subscribe), method call, custom address space
— Application authenticationYes
— Security policiesavailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256, Aes128Sha256RsaOaep, Aes256Sha256RsaPss
— User authentication"anonymous" or by user name & password
— GDS support (certificate management)No
— Number of sessions, max.32
— Number of subscriptions per session, max.25
— Sampling interval, min.25 ms
— Publishing interval, min.25 ms
— Number of server methods, max.100
— Number of inputs/outputs per server method, max.20
— Number of monitored items, recommended max.5 000; for 1 s sampling interval and 1 s send interval
— Number of server interfaces, max.10 of each "Server interfaces" / "Companion specification" type and 20 of the type "Reference namespace"
— Number of nodes for user-defined server interfaces, max.30 000
● Alarms and ConditionsNo
Further protocols
● MODBUSYes; MODBUS TCP
S7 message functions
Number of login stations for message functions, max.64
number of subscriptions, max.750
number of tags/attributes for subscriptions, max.20 000
Program alarmsYes
Number of configurable program messages, max.10 000; Program messages are generated by the "Program_Alarm" block, ProDiag or GRAPH
Number of loadable program messages in RUN, max.10 000
Number of simultaneously active program alarms
● Number of program alarms2 000
● Number of alarms for system diagnostics1 000
Test commissioning functions
Joint commission (Team Engineering)No
Status blockYes; Up to 16 simultaneously
Single stepNo
Number of breakpoints20; Breakpoints are only supported in RUN-Solo status
Status/control
● Status/control variableYes
● VariablesInputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
● Number of variables, max.
— of which status variables, max.200; per job
— of which control variables, max.200; per job
Forcing
● ForcingYes
● Forcing, variablesPeripheral inputs/outputs
● Number of variables, max.200
Diagnostic buffer
● presentYes
● Number of entries, max.3 200
— of which powerfail-proof1 000
Traces
● Number of configurable Traces8
● Memory size per trace, max.512 kbyte
Interrupts/diagnostics/status information
Diagnostics indication LED
● RUN/STOP LEDYes
● ERROR LEDYes
● MAINT LEDYes
● Connection display LINK TX/RXYes
Supported technology objects
Motion ControlNo
Controller
● PID_CompactYes; Universal PID controller with integrated optimization
● PID_3StepYes; PID controller with integrated optimization for valves
● PID-TempYes; PID controller with integrated optimization for temperature
Counting and measuringYes
Standards, approvals, certificates
Ecological footprint
● environmental product declarationYes
Global warming potential
— global warming potential, (total) [CO2 eq]570 kg
— global warming potential, (during production) [CO2 eq]96.9 kg
— global warming potential, (during operation) [CO2 eq]483 kg
— global warming potential, (after end of life cycle) [CO2 eq]-9.97 kg
Ambient conditions
Ambient temperature during operation
● horizontal installation, min.0 °C
● horizontal installation, max.60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off
● vertical installation, min.0 °C
● vertical installation, max.40 °C; Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off
Ambient temperature during storage/transportation
● min.-40 °C
● max.70 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max.5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
configuration / header
configuration / programming / header
Programming language
— LADYes
— FBDYes
— STLYes
— SCLYes
— CFCYes
— GRAPHYes
Know-how protection
● User program protection/password protectionYes
● Copy protectionNo
● Block protectionYes
Access protection
● protection of confidential configuration dataYes
● Password for displayYes
● Protection level: Write protectionYes
● Protection level: Read/write protectionYes
● Protection level: Write protection for FailsafeNo
● Protection level: Complete protectionYes
● User administrationYes
programming / cycle time monitoring / header
● lower limitadjustable minimum cycle time
● upper limitadjustable maximum cycle time
Dimensions
Width210 mm
Height147 mm
Depth129 mm
Weights
Weight, approx.2 094 g; Interface modules: 2x 18 g

CUSTOMER REVIEWS
0 Reviews
JOIN OUR NEWSLETTER
Sign up for first access to new products, sales and events.

No. 33, Lanzhu West Road, Pingshan District, Shenzhen .CN

Contact Us: Mr Qiu

Email: 1138952618@qq.com