General information |
Product type designation | CPU 1212C AC/DC/relay |
Firmware version | V4.6 |
Engineering with |
● Programming package | STEP 7 V18 or higher |
Supply voltage |
Rated value (AC) |
|
● 120 V AC | Yes |
● 230 V AC | Yes |
permissible range, lower limit (AC) | 85 V |
permissible range, upper limit (AC) | 264 V |
Line frequency |
● permissible range, lower limit | 47 Hz |
● permissible range, upper limit | 63 Hz |
Input current |
Current consumption (rated value) | 80 mA at 120 V AC; 40 mA at 240 V AC |
Current consumption, max. | 240 mA at 120 V AC; 120 mA at 240 V AC |
Inrush current, max. | 20 A; at 264 V |
I²t | 0.8 A²·s |
Output current |
for backplane bus (5 V DC), max. | 1 000 mA; Max. 5 V DC for SM and CM |
Encoder supply |
24 V encoder supply |
● 24 V | 20.4 to 28.8V |
Power loss |
Power loss, typ. | 11 W |
Memory |
Work memory |
● integrated | 100 kbyte |
Load memory |
● integrated | 2 Mbyte |
● Plug-in (SIMATIC Memory Card), max. | with SIMATIC memory card |
Backup |
● present | Yes |
● maintenance-free | Yes |
● without battery | Yes |
CPU processing times |
for bit operations, typ. | 0.08 µs; / instruction |
for word operations, typ. | 1.7 µs; / instruction |
for floating point arithmetic, typ. | 2.3 µs; / instruction |
CPU-blocks |
Number of blocks (total) | DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used |
OB |
● Number, max. | Limited only by RAM for code |
Data areas and their retentivity |
Retentive data area (incl. timers, counters, flags), max. | 14 kbyte |
Flag |
● Size, max. | 4 kbyte; Size of bit memory address area |
Local data |
● per priority class, max. | 16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB |
Address area |
Process image |
● Inputs, adjustable | 1 kbyte |
● Outputs, adjustable | 1 kbyte |
Hardware configuration |
Number of modules per system, max. | 3 comm. modules, 1 signal board, 2 signal modules |
Time of day |
Clock |
● Hardware clock (real-time) | Yes |
● Backup time | 480 h; Typical |
● Deviation per day, max. | ±60 s/month at 25 °C |
Digital inputs |
Number of digital inputs | 8; Integrated |
● of which inputs usable for technological functions | 6; HSC (High Speed Counting) |
Source/sink input | Yes |
Number of simultaneously controllable inputs |
all mounting positions |
— up to 40 °C, max. | 8 |
Input voltage |
● Rated value (DC) | 24 V |
● for signal "0" | 5 V DC at 1 mA |
● for signal "1" | 15 V DC at 2.5 mA |
Input delay (for rated value of input voltage) |
for standard inputs |
— parameterizable | 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four |
— at "0" to "1", min. | 0.2 ms |
— at "0" to "1", max. | 12.8 ms |
for interrupt inputs |
— parameterizable | Yes |
for technological functions |
— parameterizable | Single phase: 3 @ 100 kHz & 3 @ 30 kHz, differential: 3 @ 80 kHz & 3 @ 30 kHz |
Cable length |
● shielded, max. | 500 m; 50 m for technological functions |
● unshielded, max. | 300 m; for technological functions: No |
Digital outputs |
Number of digital outputs | 6; Relays |
Switching capacity of the outputs |
● with resistive load, max. | 2 A |
● on lamp load, max. | 30 W with DC, 200 W with AC |
Output delay with resistive load |
● "0" to "1", max. | 10 ms; max. |
● "1" to "0", max. | 10 ms; max. |
Relay outputs |
● Number of relay outputs | 6 |
● Number of operating cycles, max. | mechanically 10 million, at rated load voltage 100 000 |
Cable length |
● shielded, max. | 500 m |
● unshielded, max. | 150 m |
Analog inputs |
Number of analog inputs | 2 |
Input ranges |
● Voltage | Yes |
Input ranges (rated values), voltages |
● 0 to +10 V | Yes |
— Input resistance (0 to 10 V) | ≥100k ohms |
Cable length |
● shielded, max. | 100 m; twisted and shielded |
Analog outputs |
Number of analog outputs | 0 |
Analog value generation for the inputs |
Integration and conversion time/resolution per channel |
● Resolution with overrange (bit including sign), max. | 10 bit |
● Integration time, parameterizable | Yes |
● Conversion time (per channel) | 625 µs |
Encoder |
Connectable encoders |
● 2-wire sensor | Yes |
1. Interface |
Interface type | PROFINET |
Isolated | Yes |
automatic detection of transmission rate | Yes |
Autonegotiation | Yes |
Autocrossing | Yes |
Interface types |
● RJ 45 (Ethernet) | Yes |
● Number of ports | 1 |
● integrated switch | No |
Protocols |
● PROFINET IO Controller | Yes |
● PROFINET IO Device | Yes |
● SIMATIC communication | Yes |
● Open IE communication | Yes; Optionally also encrypted |
● Web server | Yes |
● Media redundancy | No |
PROFINET IO Controller |
● Transmission rate, max. | 100 Mbit/s |
Services |
— PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
— Isochronous mode | No |
— IRT | No |
— PROFIenergy | No |
— Prioritized startup | Yes |
— Number of IO devices with prioritized startup, max. | 16 |
— Number of connectable IO Devices, max. | 16 |
— Number of connectable IO Devices for RT, max. | 16 |
— of which in line, max. | 16 |
— Activation/deactivation of IO Devices | Yes |
— Number of IO Devices that can be simultaneously activated/deactivated, max. | 8 |
— Updating time | The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data. |
PROFINET IO Device |
Services |
— PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
— Isochronous mode | No |
— IRT | No |
— PROFIenergy | Yes |
— Shared device | Yes |
— Number of IO Controllers with shared device, max. | 2 |
Protocols |
Supports protocol for PROFINET IO | Yes |
PROFIsafe | No |
PROFIBUS | Yes; CM 1243-5 (master) or CM 1242-5 (slave) required |
OPC UA | Yes; OPC UA Server |
AS-Interface | Yes; CM 1243-2 required |
Protocols (Ethernet) |
● TCP/IP | Yes |
● DHCP | No |
● SNMP | Yes |
● DCP | Yes |
● LLDP | Yes |
Redundancy mode |
Media redundancy |
— MRP | No |
— MRPD | No |
SIMATIC communication |
● S7 routing | Yes |
Open IE communication |
● TCP/IP | Yes |
— Data length, max. | 8 kbyte |
● ISO-on-TCP (RFC1006) | Yes |
— Data length, max. | 8 kbyte |
● UDP | Yes |
— Data length, max. | 1 472 byte |
Web server |
● supported | Yes |
● User-defined websites | Yes |
OPC UA |
● Runtime license required | Yes; "Basic" license required |
● OPC UA Server | Yes; data access (read, write, subscribe), method call, runtime license required |
— Application authentication | Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 |
— User authentication | "anonymous" or by user name & password |
— Number of sessions, max. | 10 |
— Number of subscriptions per session, max. | 5 |
— Sampling interval, min. | 100 ms |
— Publishing interval, min. | 200 ms |
— Number of server methods, max. | 20 |
— Number of monitored items, recommended max. | 1 000 |
— Number of server interfaces, max. | 2 |
— Number of nodes for user-defined server interfaces, max. | 2 000 |
Further protocols |
● MODBUS | Yes |
communication functions / header |
S7 communication |
● supported | Yes |
● as server | Yes |
● as client | Yes |
● User data per job, max. | See online help (S7 communication, user data size) |
Number of connections |
● overall | PG Connections: 4 reserved / 4 max; HMI Connections: 12 reserved / 18 max; S7 Connections: 8 reserved / 14 max; Open User Connections: 8 reserved / 14 max; Web Connections: 2 reserved / 30 max; OPC UA Connections: 0 reserved / 10 max; Total Connections: 34 reserved / 64 max |
Test commissioning functions |
Status/control |
● Status/control variable | Yes |
● Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
Forcing |
● Forcing | Yes |
Diagnostic buffer |
● present | Yes |
Traces |
● Number of configurable Traces | 2 |
● Memory size per trace, max. | 512 kbyte |
Interrupts/diagnostics/status information |
Diagnostics indication LED |
● RUN/STOP LED | Yes |
● ERROR LED | Yes |
● MAINT LED | Yes |
Integrated Functions |
Counter |
|
● Number of counters | 6 |
● Counting frequency, max. | 100 kHz |
Frequency measurement | Yes |
controlled positioning | Yes |
Number of position-controlled positioning axes, max. | 8 |
Number of positioning axes via pulse-direction interface | Up to 4 with SB 1222 |
PID controller | Yes |
Number of alarm inputs | 4 |
Potential separation |
Potential separation digital inputs |
● Potential separation digital inputs | 500 V AC for 1 minute |
● between the channels, in groups of | 1 |
Potential separation digital outputs |
● Potential separation digital outputs | Relays |
● between the channels | No |
● between the channels, in groups of | 2 |
EMC |
Interference immunity against discharge of static electricity |
● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 | Yes |
— Test voltage at air discharge | 8 kV |
— Test voltage at contact discharge | 6 kV |
Interference immunity to cable-borne interference |
● Interference immunity on supply lines acc. to IEC 61000-4-4 | Yes |
● Interference immunity on signal cables acc. to IEC 61000-4-4 | Yes |
Interference immunity against voltage surge |
● Interference immunity on supply lines acc. to IEC 61000-4-5 | Yes |
Interference immunity against conducted variable disturbance induced by high-frequency fields |
● Interference immunity against high-frequency radiation acc. to IEC 61000-4-6 | Yes |
Emission of radio interference acc. to EN 55 011 |
● Limit class A, for use in industrial areas | Yes; Group 1 |
● Limit class B, for use in residential areas | Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 |
Degree and class of protection |
IP degree of protection | IP20 |
Standards, approvals, certificates |
Siemens Eco Profile (SEP) | Siemens EcoTech |
CE mark | Yes |
UL approval | Yes |
cULus | Yes |
FM approval | Yes |
RCM (formerly C-TICK) | Yes |
KC approval | Yes |
Marine approval | Yes |
Ecological footprint |
● environmental product declaration | Yes |
Global warming potential |
— global warming potential, (total) [CO2 eq] | 76.4 kg |
— global warming potential, (during production) [CO2 eq] | 13.8 kg |
— global warming potential, (during operation) [CO2 eq] | 63.4 kg |
— global warming potential, (after end of life cycle) [CO2 eq] | -0.885 kg |
Ambient conditions |
Free fall |
● Fall height, max. | 0.3 m; five times, in product package |
Ambient temperature during operation |
● min. | -20 °C |
● max. | 60 °C; Number of simultaneously activated inputs or outputs 4 or 3 (no adjacent points) at 60 °C horizontal or 50 °C vertical, 8 or 6 at 55 °C horizontal or 45 °C vertical |
● horizontal installation, min. | -20 °C |
● horizontal installation, max. | 60 °C |
● vertical installation, min. | -20 °C |
● vertical installation, max. | 50 °C |
Ambient temperature during storage/transportation |
● min. | -40 °C |
● max. | 70 °C |
Air pressure acc. to IEC 60068-2-13 |
● Operation, min. | 795 hPa |
● Operation, max. | 1 080 hPa |
● Storage/transport, min. | 660 hPa |
● Storage/transport, max. | 1 080 hPa |
Altitude during operation relating to sea level |
● Installation altitude, min. | -1 000 m |
● Installation altitude, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
Relative humidity |
● Operation, max. | 95 %; no condensation |
Vibrations |
● Vibration resistance during operation acc. to IEC 60068-2-6 | 2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail |
● Operation, tested according to IEC 60068-2-6 | Yes |
Shock testing |
● tested according to IEC 60068-2-27 | Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms |
Pollutant concentrations |
● SO2 at RH < 60% without condensation | S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free |
configuration / header |
configuration / programming / header |
Programming language |
— LAD | Yes |
— FBD | Yes |
— SCL | Yes |
Know-how protection |
● User program protection/password protection | Yes |
● Copy protection | Yes |
● Block protection | Yes |
Access protection |
● protection of confidential configuration data | Yes |
● Protection level: Write protection | Yes |
● Protection level: Read/write protection | Yes |
● Protection level: Complete protection | Yes |
programming / cycle time monitoring / header |
● adjustable | Yes |
Dimensions |
Width | 90 mm |
Height | 100 mm |
Depth | 75 mm |
Weights |
Weight, approx. | 425 g |