General information |
Product type designation | TM PTO 4 |
HW functional status | FS02 |
Number of channels | 4; Axes |
Product function |
● I&M data | Yes; I&M0 to I&M3 |
● Isochronous mode | Yes |
Engineering with |
● STEP 7 TIA Portal configurable/integrated from version | STEP 7 V14 or higher |
● STEP 7 configurable/integrated from version | V5.5 SP3 with GSD file / - |
● PROFINET from GSD version/GSD revision | GSDML V2.32 |
Installation type/mounting |
Rail mounting | Yes; S7-1500 mounting rail |
Supply voltage |
Load voltage L+ |
● Rated value (DC) | 24 V |
● permissible range, lower limit (DC) | 19.2 V |
● permissible range, upper limit (DC) | 28.8 V |
● Reverse polarity protection | Yes |
Input current |
Current consumption, max. | 70 mA; without load |
Power |
Power available from the backplane bus | 1.3 W |
Power loss |
Power loss, typ. | 4 W |
Address area |
Address space per module |
● Inputs | 18 byte; Per channel |
● Outputs | 10 byte; Per channel |
Digital inputs |
Number of digital inputs | 12; 3 per channel, of which 1 DIQ |
Digital inputs, parameterizable | Yes |
Input characteristic curve in accordance with IEC 61131, type 3 | Yes |
Digital input functions, parameterizable |
● Synchronization | Yes |
● Probe | Yes |
● Drive ready | Yes |
Input voltage |
● Type of input voltage | DC |
● Rated value (DC) | 24 V |
● for signal "0" | -5 ... +5 V |
● for signal "1" | +11 to +30V |
● permissible voltage at input, min. | -5 V |
● permissible voltage at input, max. | 30 V |
Input current |
● for signal "1", typ. | 2.5 mA |
Input delay (for rated value of input voltage) |
for standard inputs |
— parameterizable | Yes; none / 0.05 / 0.1 / 0.4 / 0.8 / 1.6 / 3.2 / 12.8 / 20 ms |
— at "0" to "1", min. | 4 µs; for parameterization "none" |
— at "1" to "0", min. | 4 µs; for parameterization "none" |
for technological functions |
— parameterizable | Yes |
Cable length |
● shielded, max. | 1 000 m |
● unshielded, max. | 600 m |
Digital outputs |
Number of digital outputs | 12; 3 per channel, of which 1 DIQ |
Current-sinking | Yes; For DQn.0 and DQn.1 push-pull outputs |
Current-sourcing | Yes |
Digital outputs, parameterizable | Yes |
Short-circuit protection | Yes; electronic/thermal |
● Response threshold, typ. | 0.2 A for DQn.0 and DQn.1, 0.9 A for DIQn.2 |
Controlling a digital input | Yes |
Digital output functions, parameterizable |
● PTO (pulse train output) signal interface |
|
— 24 V asymmetrical | Yes |
— RS 422 symmetrical | Yes |
— TTL (5 V) asymmetrical | Yes |
● PTO (pulse train output) signal type |
|
— Pulse and direction | Yes |
— Count up, count down | Yes |
— Incremental encoder (A, B phase shift) | Yes |
— Incremental encoder (A, B phase shift, quadruple) | Yes |
Switching capacity of the outputs |
● with resistive load, max. | 0.1 A; 0.5 A for DIQn.2 |
● on lamp load, max. | 1 W; 5 W for DIQn.2 |
Load resistance range |
● lower limit | 240 Ω; 48 ohms for DIQn.2 |
● upper limit | 12 kΩ |
Output voltage |
● Type of output voltage | DC |
● for signal "1", min. | 23.2 V; L+ (-0.8 V), L+ (-1.3 V) for DIQn.2 |
Output current |
● for signal "1" rated value | 0.1 A; 0.5 A for DIQn.2 |
● for signal "1" permissible range, max. | 0.12 A; 0.6 A for DIQn.2 |
● for signal "1" minimum load current | 2 mA |
● for signal "0" residual current, max. | 0.5 mA |
Output delay with resistive load |
● "0" to "1", typ. | 1 µs; 28 µs for DIQn.2 |
● "1" to "0", typ. | 1 µs; 25 µs for DIQn.2 |
Switching frequency |
● with resistive load, max. | 1 kHz; For DIQn.2 |
● with inductive load, max. | 0.5 Hz; According to IEC 60947-5-1, DC-13, for DIQn.2 |
● on lamp load, max. | 10 Hz; For DIQn.2 |
● For signal interface 24 V asymmetrical | 200 kHz; With DQn.0 and DQn.1 |
● For signal interface RS 422 symmetrical | 1 MHz |
● For signal interface TTL (5 V) asymmetrical | 200 kHz |
Cable length |
● shielded, max. | 600 m; Cable length, RS 422 / TTL Siemens Type 6FX2001-5: 125 kHz, 320 meters shielded, max.; 250 kHz, 160 meters shielded, max.; 500 kHz, 60 meters shielded, max.; 1 MHz, 32 meters shielded, max. 24 V (DQn.x / DIQn.2): 10 kHz, 600 meters, shielded, max. 200 kHz, 50 meters shielded, max. |
Isochronous mode |
Bus cycle time (TDP), min. | 250 µs; 375 µs if all 4 channels are used |
Jitter, max. | 1 µs |
Interrupts/diagnostics/status information |
Diagnostics function | Yes |
Alarms |
● Diagnostic alarm | Yes |
Diagnoses |
● Monitoring the supply voltage | Yes |
● Short-circuit | Yes; Thermal overload protection |
● Group error | Yes |
Diagnostics indication LED |
● RUN LED | Yes; green LED |
● ERROR LED | Yes; red LED |
● MAINT LED | Yes; Yellow LED |
● Monitoring of the supply voltage (PWR-LED) | Yes; green LED |
● Channel status display | Yes; green LED |
● for channel diagnostics | Yes; red LED |
Potential separation |
Potential separation channels |
● between the channels | No |
● between the channels and backplane bus | Yes |
● Between the channels and load voltage L+ | No |
Isolation |
Isolation tested with | 707 V DC (type test) |
Ambient conditions |
Ambient temperature during operation |
● horizontal installation, min. | 0 °C |
● horizontal installation, max. | 60 °C; Observe derating |
● vertical installation, min. | 0 °C |
● vertical installation, max. | 40 °C; Observe derating |
Altitude during operation relating to sea level |
● Installation altitude above sea level, max. | 5 000 m; restrictions for installation altitudes > 2 000 m, see ET 200MP system manual |
Decentralized operation |
to SIMATIC S7-300 | Yes; Via control and feedback interface |
to SIMATIC S7-400 | Yes; Via control and feedback interface |
to SIMATIC S7-1200 | Yes |
to SIMATIC S7-1500 | Yes |
to standard PROFINET controller | Yes; Via control and feedback interface |
Dimensions |
Width | 35 mm |
Height | 147 mm |
Depth | 129 mm |
Weights |
Weight, approx. | 300 g |