SIEMENS S7-1500 Process module Interface module 6ES7553-1AA00-0AB0

15 review

Product Code:

6952.37 0.00
SIMATIC S7-1500, TM PTO 4 interface module for stepper drives 4 channels pulse train output PTO: 24 V, RS-422, 5 V, 2 DI, 1 DQ 24VDC per channel
Quantity

Subtotal: $6952.37

Product details

General information
Product type designationTM PTO 4
HW functional statusFS02
Number of channels4; Axes
Product function
● I&M dataYes; I&M0 to I&M3
● Isochronous modeYes
Engineering with
● STEP 7 TIA Portal configurable/integrated from versionSTEP 7 V14 or higher
● STEP 7 configurable/integrated from versionV5.5 SP3 with GSD file / -
● PROFINET from GSD version/GSD revisionGSDML V2.32
Installation type/mounting
Rail mountingYes; S7-1500 mounting rail
Supply voltage
Load voltage L+
● Rated value (DC)24 V
● permissible range, lower limit (DC)19.2 V
● permissible range, upper limit (DC)28.8 V
● Reverse polarity protectionYes
Input current
Current consumption, max.70 mA; without load
Power
Power available from the backplane bus1.3 W
Power loss
Power loss, typ.4 W
Address area
Address space per module
● Inputs18 byte; Per channel
● Outputs10 byte; Per channel
Digital inputs
Number of digital inputs12; 3 per channel, of which 1 DIQ
Digital inputs, parameterizableYes
Input characteristic curve in accordance with IEC 61131, type 3Yes
Digital input functions, parameterizable
● SynchronizationYes
● ProbeYes
● Drive readyYes
Input voltage
● Type of input voltageDC
● Rated value (DC)24 V
● for signal "0"-5 ... +5 V
● for signal "1"+11 to +30V
● permissible voltage at input, min.-5 V
● permissible voltage at input, max.30 V
Input current
● for signal "1", typ.2.5 mA
Input delay (for rated value of input voltage)
for standard inputs
— parameterizableYes; none / 0.05 / 0.1 / 0.4 / 0.8 / 1.6 / 3.2 / 12.8 / 20 ms
— at "0" to "1", min.4 µs; for parameterization "none"
— at "1" to "0", min.4 µs; for parameterization "none"
for technological functions
— parameterizableYes
Cable length
● shielded, max.1 000 m
● unshielded, max.600 m
Digital outputs
Number of digital outputs12; 3 per channel, of which 1 DIQ
Current-sinkingYes; For DQn.0 and DQn.1 push-pull outputs
Current-sourcingYes
Digital outputs, parameterizableYes
Short-circuit protectionYes; electronic/thermal
● Response threshold, typ.0.2 A for DQn.0 and DQn.1, 0.9 A for DIQn.2
Controlling a digital inputYes
Digital output functions, parameterizable
● PTO (pulse train output) signal interface
— 24 V asymmetricalYes
— RS 422 symmetricalYes
— TTL (5 V) asymmetricalYes
● PTO (pulse train output) signal type
— Pulse and directionYes
— Count up, count downYes
— Incremental encoder (A, B phase shift)Yes
— Incremental encoder (A, B phase shift, quadruple)Yes
Switching capacity of the outputs
● with resistive load, max.0.1 A; 0.5 A for DIQn.2
● on lamp load, max.1 W; 5 W for DIQn.2
Load resistance range
● lower limit240 Ω; 48 ohms for DIQn.2
● upper limit12 kΩ
Output voltage
● Type of output voltageDC
● for signal "1", min.23.2 V; L+ (-0.8 V), L+ (-1.3 V) for DIQn.2
Output current
● for signal "1" rated value0.1 A; 0.5 A for DIQn.2
● for signal "1" permissible range, max.0.12 A; 0.6 A for DIQn.2
● for signal "1" minimum load current2 mA
● for signal "0" residual current, max.0.5 mA
Output delay with resistive load
● "0" to "1", typ.1 µs; 28 µs for DIQn.2
● "1" to "0", typ.1 µs; 25 µs for DIQn.2
Switching frequency
● with resistive load, max.1 kHz; For DIQn.2
● with inductive load, max.0.5 Hz; According to IEC 60947-5-1, DC-13, for DIQn.2
● on lamp load, max.10 Hz; For DIQn.2
● For signal interface 24 V asymmetrical200 kHz; With DQn.0 and DQn.1
● For signal interface RS 422 symmetrical1 MHz
● For signal interface TTL (5 V) asymmetrical200 kHz
Cable length
● shielded, max.600 m; Cable length, RS 422 / TTL Siemens Type 6FX2001-5: 125 kHz, 320 meters shielded, max.; 250 kHz, 160 meters shielded, max.; 500 kHz, 60 meters shielded, max.; 1 MHz, 32 meters shielded, max. 24 V (DQn.x / DIQn.2): 10 kHz, 600 meters, shielded, max. 200 kHz, 50 meters shielded, max.
Isochronous mode
Bus cycle time (TDP), min.250 µs; 375 µs if all 4 channels are used
Jitter, max.1 µs
Interrupts/diagnostics/status information
Diagnostics functionYes
Alarms
● Diagnostic alarmYes
Diagnoses
● Monitoring the supply voltageYes
● Short-circuitYes; Thermal overload protection
● Group errorYes
Diagnostics indication LED
● RUN LEDYes; green LED
● ERROR LEDYes; red LED
● MAINT LEDYes; Yellow LED
● Monitoring of the supply voltage (PWR-LED)Yes; green LED
● Channel status displayYes; green LED
● for channel diagnosticsYes; red LED
Potential separation
Potential separation channels
● between the channelsNo
● between the channels and backplane busYes
● Between the channels and load voltage L+No
Isolation
Isolation tested with707 V DC (type test)
Ambient conditions
Ambient temperature during operation
● horizontal installation, min.0 °C
● horizontal installation, max.60 °C; Observe derating
● vertical installation, min.0 °C
● vertical installation, max.40 °C; Observe derating
Altitude during operation relating to sea level
● Installation altitude above sea level, max.5 000 m; restrictions for installation altitudes > 2 000 m, see ET 200MP system manual
Decentralized operation
to SIMATIC S7-300Yes; Via control and feedback interface
to SIMATIC S7-400Yes; Via control and feedback interface
to SIMATIC S7-1200Yes
to SIMATIC S7-1500Yes
to standard PROFINET controllerYes; Via control and feedback interface
Dimensions
Width35 mm
Height147 mm
Depth129 mm
Weights
Weight, approx.300 g