General information |
Product type designation | TM Count 2x24V |
Firmware version | V2.0 |
● FW update possible | Yes |
Product function |
● I&M data | Yes; I&M0 to I&M3 |
● Isochronous mode | Yes |
Engineering with |
● STEP 7 TIA Portal configurable/integrated from version | V16 with HSP 0332 / V17 |
● PROFIBUS from GSD version/GSD revision | GSD Revision 5 |
● PROFINET from GSD version/GSD revision | V2.3 / - |
Installation type/mounting |
Rail mounting | Yes; S7-1500 mounting rail |
Supply voltage |
Load voltage L+ |
● Rated value (DC) | 24 V |
● permissible range, lower limit (DC) | 19.2 V |
● permissible range, upper limit (DC) | 28.8 V |
● Reverse polarity protection | Yes |
Input current |
Current consumption, max. | 75 mA; without load |
Encoder supply |
Number of outputs | 1; A common 24V encoder supply for both channels |
24 V encoder supply |
● 24 V | Yes; L+ (-0.8 V) |
● Short-circuit protection | Yes |
● Output current, max. | 1 A; total current of all encoders/channels |
Power |
Power available from the backplane bus | 1.3 W |
Power loss |
Power loss, typ. | 4 W |
Address area |
Address space per module |
● Inputs | 32 byte; 16 bytes per channel; 4 bytes for fast mode |
● Outputs | 24 byte; 12 bytes per channel; 4 bytes for Motion Control, 0 bytes for fast mode |
Digital inputs |
Number of digital inputs | 6; 3 per channel |
Digital inputs, parameterizable | Yes |
Input characteristic curve in accordance with IEC 61131, type 3 | Yes |
Digital input functions, parameterizable |
● Gate start/stop | Yes |
● Capture | Yes |
● Synchronization | Yes |
● Freely usable digital input | Yes |
● Probe | Yes |
Input voltage |
● Type of input voltage | DC |
● Rated value (DC) | 24 V |
● for signal "0" | -5 ... +5 V |
● for signal "1" | +11 to +30V |
● permissible voltage at input, min. | -30 V; -5 V continuous, -30 V brief reverse polarity protection |
● permissible voltage at input, max. | 30 V |
Input current |
● for signal "1", typ. | 2.5 mA |
Input delay (for rated value of input voltage) |
for standard inputs |
— parameterizable | Yes; none / 0.05 / 0.1 / 0.4 / 0.8 / 1.6 / 3.2 / 12.8 / 20 ms |
— at "0" to "1", min. | 6 µs; for parameterization "none" |
— at "1" to "0", min. | 6 µs; for parameterization "none" |
for technological functions |
— parameterizable | Yes |
Cable length |
● shielded, max. | 1 000 m |
● unshielded, max. | 600 m |
Digital outputs |
Type of digital output | Transistor |
Number of digital outputs | 4; 2 per channel |
Digital outputs, parameterizable | Yes |
Short-circuit protection | Yes; electronic/thermal |
● Response threshold, typ. | 1 A |
Limitation of inductive shutdown voltage to | L+ (-53 V) |
Controlling a digital input | Yes |
Digital output functions, parameterizable |
● Switching tripped by comparison values | Yes |
● Freely usable digital output | Yes |
Switching capacity of the outputs |
● with resistive load, max. | 0.5 A; Per digital output |
● on lamp load, max. | 5 W |
Load resistance range |
● lower limit | 48 Ω |
● upper limit | 12 kΩ |
Output voltage |
● Type of output voltage | DC |
● for signal "1", min. | 23.2 V; L+ (-0.8 V) |
Output current |
● for signal "1" rated value | 0.5 A; Per digital output |
● for signal "1" permissible range, max. | 0.6 A; Per digital output |
● for signal "1" minimum load current | 2 mA |
● for signal "0" residual current, max. | 0.5 mA |
Output delay with resistive load |
● "0" to "1", max. | 50 µs |
● "1" to "0", max. | 50 µs |
Switching frequency |
● with resistive load, max. | 10 kHz |
● with inductive load, max. | 0.5 Hz; Acc. to IEC 60947-5-1, DC-13; observe derating curve |
● on lamp load, max. | 10 Hz |
Total current of the outputs |
● Current per module, max. | 2 A |
Cable length |
● shielded, max. | 1 000 m |
● unshielded, max. | 600 m |
Encoder |
Connectable encoders |
● 2-wire sensor | Yes |
— permissible quiescent current (2-wire sensor), max. | 1.5 mA |
Encoder signals, incremental encoder (asymmetrical) |
● Input voltage | 24 V |
● Input frequency, max. | 200 kHz |
● Counting frequency, max. | 800 kHz; with quadruple evaluation |
● Cable length, shielded, max. | 600 m; depending on input frequency, encoder and cable quality; max. 50 m at 200 kHz |
● Signal filter, parameterizable | Yes |
● Incremental encoder with A/B tracks, 90° phase offset | Yes |
● Incremental encoder with A/B tracks, 90° phase offset and zero track | Yes |
● pulse encoder | Yes |
● pulse encoder with direction | Yes |
● pulse encoder with one impulse signal per count direction | Yes |
Interface types |
● Source/sink input | Yes |
● Input characteristic curve in accordance with IEC 61131, type 3 | Yes |
Interrupts/diagnostics/status information |
Alarms |
● Diagnostic alarm | Yes |
● Hardware interrupt | Yes |
Diagnoses |
● Monitoring the supply voltage | Yes |
● Wire-break | Yes |
● Short-circuit | Yes |
● A/B transition error at incremental encoder | Yes |
Diagnostics indication LED |
● RUN LED | Yes; green LED |
● ERROR LED | Yes; red LED |
● MAINT LED | Yes; Yellow LED |
● Monitoring of the supply voltage (PWR-LED) | Yes; green LED |
● Channel status display | Yes; green LED |
● for channel diagnostics | Yes; red LED |
Integrated Functions |
Counter | Yes |
● Number of counters | 2 |
● Counting frequency, max. | 800 kHz; with quadruple evaluation |
Fast mode | Yes |
Counting functions |
● Can be used with TO High_Speed_Counter | Yes |
● Continuous counting | Yes |
● Counter response parameterizable | Yes |
● Hardware gate via digital input | Yes |
● Software gate | Yes |
● Event-controlled stop | Yes |
● Synchronization via digital input | Yes |
● Counting range, parameterizable | Yes |
Comparator |
— Number of comparators | 2; Per channel |
— Direction dependency | Yes |
— Can be changed from user program | Yes |
Position detection |
● Incremental acquisition | Yes |
● Suitable for S7-1500 Motion Control | Yes |
● suitable for SIMOTION | Yes |
Measuring functions |
● Measuring time, parameterizable | Yes |
● Dynamic measurement period adjustment | Yes |
● Number of thresholds, parameterizable | 2 |
Measuring range |
— Frequency measurement, min. | 0.04 Hz |
— Frequency measurement, max. | 800 kHz |
— Cycle duration measurement, min. | 1.25 µs |
— Cycle duration measurement, max. | 25 s |
Accuracy |
— Frequency measurement | 100 ppm; depending on measuring interval and signal evaluation |
— Cycle duration measurement | 100 ppm; depending on measuring interval and signal evaluation |
— Velocity measurement | 100 ppm; depending on measuring interval and signal evaluation |
Potential separation |
Potential separation channels |
● between the channels | No |
● between the channels and backplane bus | Yes |
● Between the channels and load voltage L+ | No |
Isolation |
Isolation tested with | 707 V DC (type test) |
Ambient conditions |
Ambient temperature during operation |
● horizontal installation, min. | -30 °C |
● horizontal installation, max. | 60 °C; Please note derating for inductive loads |
● vertical installation, min. | -30 °C |
● vertical installation, max. | 40 °C; Please note derating for inductive loads |
Altitude during operation relating to sea level |
● Installation altitude above sea level, max. | 5 000 m; restrictions for installation altitudes > 2 000 m, see ET 200MP system manual |
Decentralized operation |
to SIMATIC S7-300 | Yes |
to SIMATIC S7-400 | Yes |
to SIMATIC S7-1200 | Yes |
to SIMATIC S7-1500 | Yes |
to standard PROFIBUS master | Yes |
to standard PROFINET controller | Yes |
Dimensions |
Width | 35 mm |
Height | 147 mm |
Depth | 129 mm |
Weights |
Weight, approx. | 250 g |